DOOR FIELD TAKEOFF

Walk it. Tap it.
Keep moving.

Capture door size, handing, and single-leaf or pair assemblies while you walk the job. BidSimp keeps the opening count and door leaf quantities running for you.

Not sure of the hand? Open the Door Handing Cheat Sheet

INPUT · 01

Capture an opening

Autosaved on this device.

Blank = auto-numbered.

Assembly

1 opening · 1 leaf.

Single-leaf width.

Door Handing / Swing

Choose hand from the reference side.

Size stays selected after each entry. Handing and the custom note clear so the next opening is deliberate.

RUNNING TAKEOFF

Door quantities

Openings0
Door Leaves0
Pair Assemblies0

No doors added yet. Your field log will build here.

OUTPUT · 02

Grouped quantities

Matching size, assembly, hand / pair condition, and notes are grouped together.

Add doors above to build the quantity summary.

Paste into email, text, notes, or another estimate.
PDF / Print Details (Optional)Add project information to your field takeoff.

These fields are optional and do not affect the takeoff.

QUICK DEMO

See the Door Field Takeoff Tool in action.

Watch a quick field-style walkthrough of capturing door sizes, handing, locations, and notes while building a running takeoff.

Current pair logic

A pair is one opening with two equal door leaves. Example: one 6'-0" x 7'-0" pair is counted as 1 opening and 2 leaves at 3'-0" x 7'-0" each. For pairs, choose the active leaf hand when there is one, or record Both Active or No Active Leaf.

DOOR FIELD TAKEOFF GUIDE

How to use the Door Field Takeoff Tool

Door Field Takeoff is built for walking a project and recording openings quickly. Each entry keeps the door or location, overall size, handing or pair condition, assembly type, and a custom note. BidSimp then produces opening totals, leaf totals, grouped quantities, an individual field log, copied text, and a printable PDF.

SINGLE LEAFEntered width is the door width

One entry counts as one opening and one leaf.

PAIREntered width is overall pair width

One entry counts as one opening and two equal leaves.

AUTOSAVEStored in the current browser

The field log is saved locally on the device until it is cleared or browser storage is removed.

Single-leaf and pair size conventions

For a single-leaf door, a 3'-0" × 7'-0" entry means one 3'-0" leaf in one opening. For a pair, a 6'-0" × 7'-0" entry means one 6'-0" overall opening with two equal 3'-0" leaves. The grouped summary preserves the overall pair size and also identifies the equal leaf size.

Custom dimensions are supported and displayed to the nearest 1/16". Confirm whether the project uses nominal door sizes, frame opening sizes, rough openings, or field-measured clear dimensions before mixing information from different sources.

Handing and pair conditions

Single doors use LH, RH, LHR, or RHR. Pair entries can identify the active leaf as LH, RH, LHR, or RHR, or record Both Active or No Active Leaf. The tool records the condition you choose; it does not determine handing from a floor plan or verify the project's reference-side convention.

When door handing is uncertain, record a note and verify it against the approved door schedule, elevations, hardware sets, frame details, and manufacturer or supplier convention before ordering.

WORKED EXAMPLE

Three openings recorded during a job walk

  1. Door 101: 3'-0" × 7'-0", RH, single leaf.
  2. Door 102: 3'-0" × 7'-0", RH, single leaf.
  3. Lobby Pair: 6'-0" × 7'-0", RH Active, pair.

The totals show 3 openings, 4 leaves, and 1 pair assembly. The two matching single doors group together at quantity 2. The pair remains separate and is shown as two equal 3'-0" leaves.

How entries are grouped

The grouped summary combines entries only when assembly type, overall width, height, hand or pair condition, and normalized note match. Door numbers and locations remain in the field log so you can trace each opening even when several doors share the same material condition.

Use notes for distinctions that affect purchasing or review, such as frame type, material, rating, glazing, undercut, existing condition, active leaf, or an unresolved field question. Entries with different notes remain separate in the grouped quantity summary.

Common door takeoff mistakes

  • Mixing door-leaf size, frame opening, rough opening, and field clear opening dimensions.
  • Entering a pair width as though it were the width of each leaf.
  • Calling handing from the wrong reference side or without checking reverse swing.
  • Grouping doors that have different ratings, frame profiles, hardware, glazing, or material.
  • Relying on the grouped quantity without preserving door numbers and locations.

Verify before ordering

  • Door and frame schedules, elevations, details, hardware sets, specifications, and addenda.
  • Nominal size, actual leaf size, frame type, jamb depth, anchors, throat, and wall condition.
  • Handing, active and inactive leaves, astragals, coordinators, flush bolts, and egress requirements.
  • Fire rating, labeling, glazing, louvers, finishes, undercuts, thresholds, and accessibility.
  • Existing field conditions, demolition, reuse, lead times, delivery, and supplier conventions.
Help make BidSimp better.Something missing, confusing, or just plain wrong? Tell us.

Field takeoff aid: Verify door sizes, handing, active/inactive leaf conditions, frame requirements, hardware sets, fire ratings, glazing, project drawings, specifications, and supplier requirements before ordering or construction. Terms & Disclaimer